Skip to main content

Research Repository

Advanced Search

Effect of Knee, Ankle and Hip Joint Replacements on Vitamin E Infused Highly Crosslinked UHMWPE Wear Particles Size, Shape and Morphologies Using a New Modified Base Digestion Method (2015)
Conference Proceeding
Lal, S., & Wu, J. (2015). Effect of Knee, Ankle and Hip Joint Replacements on Vitamin E Infused Highly Crosslinked UHMWPE Wear Particles Size, Shape and Morphologies Using a New Modified Base Digestion Method. In Proceedings of the 7th International UHMWPE Meeting. Philadelphia, PA, USA. October 22 and 23, 2015

A mathematical model of the eye lens epithelium of mammals that predicts cell density profiles in the ageing lens. (2015)
Conference Proceeding
Quinlan, R., Wu, J., Wu, W., Saunter, C., & Girkin, J. (2015). A mathematical model of the eye lens epithelium of mammals that predicts cell density profiles in the ageing lens.

Purpose: To develop a mathematical model of the mammalian eye lens epithelium that is independent of the lens size and that accounts for the change in cell density from the anterior pole to the meridional rows at the lens equator. The model aims to p... Read More about A mathematical model of the eye lens epithelium of mammals that predicts cell density profiles in the ageing lens..

Prosim Simulator Wear Study of 60mm Diameter Zirconia Toughened Alumina Composite Hip Bearings: The Effect of High Cup Inclination Angle and Microseparation (2011)
Conference Proceeding
Giddings, D., Wu, J., Mak, S., & Khan, I. (2011). Prosim Simulator Wear Study of 60mm Diameter Zirconia Toughened Alumina Composite Hip Bearings: The Effect of High Cup Inclination Angle and Microseparation. In P. Cann, & D. Dini (Eds.), Proceedings of the International Conference on BioTribology ICoBT 2011, Imperial College London

Numerical Prediction on Mechanical Contacts Vanguard Knee Joint replacements Tested in the Displacement-Controlled Prosim Simulator (2009)
Conference Proceeding
Wang, Q., & Wu, J. (2009). Numerical Prediction on Mechanical Contacts Vanguard Knee Joint replacements Tested in the Displacement-Controlled Prosim Simulator. In Proceedings of IMeChE Knee Arthroplasty: From Early Intervention to Revision, Lincoln's Inn Fields, London, 30 April 2009 - 02 May 2009 (289-292)

Exploring the mechanical environments in total knee replacements (TKR) has been indentified to be useful to understand the early failure of the prostheses. The severe damages observed on the retrieved polyethylene tibial component implicate that the... Read More about Numerical Prediction on Mechanical Contacts Vanguard Knee Joint replacements Tested in the Displacement-Controlled Prosim Simulator.

Anisotropic plastic deformation of glassy polymers with process-induced molecular orientation (2003)
Conference Proceeding
Buckley, C., & Wu, J. (2003). Anisotropic plastic deformation of glassy polymers with process-induced molecular orientation.

The constitutive modelling of glassy thermoplastics is extended to the case of anisotropy arising from processinduced molecular orientation. The basis of the work is the Glass-Rubber model framework, known to capture well the constitutive response of... Read More about Anisotropic plastic deformation of glassy polymers with process-induced molecular orientation.