Dr Christopher Donaghy Spargo christopher.spargo@durham.ac.uk
Academic Visitor
Leakage Inductance of a Prototyped Single Tooth Wound Synchronous Reluctance Motor
Donaghy-Spargo, C.M.; Mecrow, B.C.; Widmer, J.D.
Authors
B.C. Mecrow
J.D. Widmer
Abstract
This paper explores the inductance characteristics present in single tooth wound synchronous reluctance motors, specifically the stator leakage inductance. Despite the nature of the single tooth design resulting in increased air gap harmonic content, having has consequences for the machines' design, performance & operation, the topology has been shown previously to be competitive for high efficiency drives. A key design constraint in the design of synchronous reluctance motors is maximizing the direct axis inductance and minimizing the quadrature axis inductance for a high saliency ratio. The effect of increased leakage inductance on this saliency ratio is explored with emphasis placed on design aspects of such single tooth wound synchronous reluctance motors. It is shown that careful design of the machine is required to maximize the saliency ratio in this machine topology and that the dominant leakage inductance component is the air gap harmonic leakage.
Citation
Donaghy-Spargo, C., Mecrow, B., & Widmer, J. (2017, December). Leakage Inductance of a Prototyped Single Tooth Wound Synchronous Reluctance Motor. Presented at International Electrical Machines and Drives (IEMDC) Conference, Miami, Florida
Presentation Conference Type | Conference Paper (published) |
---|---|
Conference Name | International Electrical Machines and Drives (IEMDC) Conference |
Acceptance Date | Feb 23, 2017 |
Online Publication Date | Aug 8, 2017 |
Publication Date | Aug 8, 2017 |
Deposit Date | Mar 19, 2017 |
Publicly Available Date | Nov 8, 2017 |
Publisher | Institute of Electrical and Electronics Engineers |
Pages | 556-561 |
Book Title | 2017 IEEE International Electric Machines and Drives Conference (IEMDC) ; proceedings. |
ISBN | 9781509042821 |
DOI | https://doi.org/10.1109/iemdc.2017.8002059 |
Public URL | https://durham-repository.worktribe.com/output/1148848 |
Files
Accepted Conference Proceeding
(812 Kb)
PDF
Copyright Statement
© 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
You might also like
Simplified Automatic Fault Detection in Wind Turbine Induction Generators
(2020)
Journal Article
Use of Fractional-Conductor Windings and Semi-Magnetic Slot Wedges in Synchronous Machines
(2019)
Journal Article
Transient Skin Effect in Power Electronic Applications
(2019)
Journal Article
Evaluating Suitable Semiconducting Materials for Cryogenic Power Electronics
(2019)
Journal Article
Downloadable Citations
About Durham Research Online (DRO)
Administrator e-mail: dro.admin@durham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search