Resolution correction in EELS
(1998)
Journal Article
Toth, J., Varga, D., Cserny, I., Kover, L., Gruzza, B., Zeze, D., …Gergely, G. (1998). Resolution correction in EELS. Vacuum, 50(3-4), 473-479
Outputs (1468)
Surface topography of retrieved PCA acetabular liners: proposal of anovel wear mechanism (1998)
Journal Article
Elfick, A., Hall, R., Unsworth, A., & Pinder, I. (1998). Surface topography of retrieved PCA acetabular liners: proposal of anovel wear mechanism. Journal of materials science letters (Dordrecht. Online), 17(13), 1085-1088. https://doi.org/10.1023/a%3A1006623830833
Wear in retrieved acetabular components - Effect of femoral head radiusand patient parameters (1998)
Journal Article
Elfick, A., Hall, R., Pinder, I., & Unsworth, A. (1998). Wear in retrieved acetabular components - Effect of femoral head radiusand patient parameters. Journal of Arthroplasty, 13(3), 291-295
AES and EELS study of aluminium oxide thin films (1998)
Journal Article
Kapsa, R., Stara, I., Zeze, D., Gruzza, B., & Matolin, V. (1998). AES and EELS study of aluminium oxide thin films. Thin Solid Films, 317(1-2), 77-80
The effect of surface topograph of retrieved femoral heads on the wearof UHMWPE sockets (1997)
Journal Article
Hall, R., Siney, P., Unsworth, A., & Wroblewski, B. (1997). The effect of surface topograph of retrieved femoral heads on the wearof UHMWPE sockets. Medical Engineering and Physics, 19(8), 711-719
Development of a six station knee wear simulator and preliminary wearresults (1997)
Journal Article
Burgess, I., Kolar, M., Cunningham, J., & Unsworth, A. (1997). Development of a six station knee wear simulator and preliminary wearresults. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 211(1), 37-47
Further studies into proximal interphalangeal joint dimensions for thedesign of a surface replacement prosthesis: medullary cavities andtransverse plane shapes (1997)
Journal Article
Ash, H., & Unsworth, A. (1997). Further studies into proximal interphalangeal joint dimensions for thedesign of a surface replacement prosthesis: medullary cavities andtransverse plane shapes. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 211(5), 377-390
Quantum Chaos in an Ion Trap: The Delta-Kicked Harmonic Oscillator. (1997)
Journal Article
Gardiner, S., Cirac, J., & Zoller, P. (1997). Quantum Chaos in an Ion Trap: The Delta-Kicked Harmonic Oscillator. Physical Review Letters, 79(24), 4790-4793. https://doi.org/10.1103/physrevlett.79.4790We propose an experimental configuration, within an ion trap, by which a quantum mechanical delta-kicked harmonic oscillator could be realized, and investigated. We show how to directly measure the sensitivity of the ion motion to small variations in... Read More about Quantum Chaos in an Ion Trap: The Delta-Kicked Harmonic Oscillator..
Porosity Modelling of Brush Seals. (1997)
Journal Article
Chew, J., & Hogg, S. (1997). Porosity Modelling of Brush Seals. Journal of Tribology, 119(4), 769-775
Finite element approximation of a model for phase separation of a multi-component alloy with non-smooth free energy (1997)
Journal Article
Blowey, J., & Barrett, J. (1997). Finite element approximation of a model for phase separation of a multi-component alloy with non-smooth free energy. Numerische Mathematik, 77, 1-34