Coordinated Control of DC Voltage Magnitudes and State of Charges in a Cluster of DC Microgrids
(2016)
Presentation / Conference Contribution
Shahbazi, M., Kazemtabrizi, B., & Dent, C. (2016, December). Coordinated Control of DC Voltage Magnitudes and State of Charges in a Cluster of DC Microgrids. Presented at IEEE PES Innovative Smart Grid Technologies, Europe, Ljubljana, Slovenia
Dr Mahmoud Shahbazi's Outputs (5)
Power Electronic Converters in Microgrid Applications (2016)
Book Chapter
Shahbazi, M., & Khorsandi, A. (2016). Power Electronic Converters in Microgrid Applications. In M. Mahmoud (Ed.), Microgrid: Advanced Control Methods and Renewable Energy System Integration. Elsevier
Improvement of Post-Fault Performance of a Cascaded H-bridge Multilevel Inverter (2016)
Journal Article
Ouni, S., Zolghadri, M., Khodabandeh, M., Shahbazi, M., Rodriguez, J., Oraee, H., …Schmeisser, A. (2017). Improvement of Post-Fault Performance of a Cascaded H-bridge Multilevel Inverter. IEEE Transactions on Industrial Electronics, 64(4), 2779-2788. https://doi.org/10.1109/tie.2016.2632058This paper is focused on improving the post-fault performance of Cascaded H-bridge Multilevel Inverters by decreasing the common mode voltage. First, an algorithm is proposed to determine the optimal post-fault state among all possible states which h... Read More about Improvement of Post-Fault Performance of a Cascaded H-bridge Multilevel Inverter.
Open-circuit switch fault tolerant wind energy conversion system based on six/five-leg reconfigurable converter (2016)
Journal Article
Shahbazi, M., Saadate, S., Poure, P., & Zolghadri, M. (2016). Open-circuit switch fault tolerant wind energy conversion system based on six/five-leg reconfigurable converter. Electric Power Systems Research, 137, 104-112. https://doi.org/10.1016/j.epsr.2016.04.004In this paper, an FPGA-controlled fault tolerant back-to-back converter for DFIG-based wind energy conversion application is studied. Before an open-circuit failure in one of the semiconductors, the fault tolerant converter operates as a conventional... Read More about Open-circuit switch fault tolerant wind energy conversion system based on six/five-leg reconfigurable converter.
T-Type Direct AC/AC Converter Structure (2016)
Journal Article
Khodabandeh, M., Zolghadri, M., Shahbazi, M., & Noroozi, N. (2016). T-Type Direct AC/AC Converter Structure. IET Power Electronics, 9(7), 1426-1436. https://doi.org/10.1049/iet-pel.2015.0151In this study, a novel T-type topology for single-phase direct AC/AC conversion is proposed. In this topology, frequency changing takes place directly (without common DC voltage bus) through three converters that are connected in a T structure. Unity... Read More about T-Type Direct AC/AC Converter Structure.