Inter-laminar short-circuit faults between the laminations of electrical machines, and other magnetic devices, have been one of the major challenges for the suppliers and customers of electrical steels. Extra power losses caused by inter-laminar faults depend on many factors including the location of the fault points. In this study, fundamental definitions and concepts of inter-laminar short-circuit faults, effect of inter-laminar faults on configuration of the magnetic cores and FEM verification are presented. Experimental works were performed to study the effect of inter-laminar faults with different configurations on the total power loss to distinguish and locate the critical and destructive faults. In the relevant studies, artificial short circuits of different configurations were applied between laminations of packs of four Epstein size laminations of 3% grain oriented silicon steel. Extra power losses caused by the inter-laminar faults were measured and the results were analysed.
Hamzehbahmani, H., Jenkins, K., Anderson, P., & Lindenmo, M. (2016). Experimental study on inter-laminar short-circuit faults at random positions in laminated magnetic cores. IET Electric Power Applications, 10(7), 604-613. https://doi.org/10.1049/iet-epa.2015.0585
Journal Article Type | Article |
---|---|
Acceptance Date | Mar 10, 2016 |
Online Publication Date | Jul 25, 2016 |
Publication Date | Jul 25, 2016 |
Deposit Date | Aug 13, 2018 |
Publicly Available Date | Feb 5, 2019 |
Journal | IET Electric Power Applications |
Print ISSN | 1751-8660 |
Electronic ISSN | 1751-8679 |
Publisher | Institution of Engineering and Technology (IET) |
Peer Reviewed | Peer Reviewed |
Volume | 10 |
Issue | 7 |
Pages | 604-613 |
DOI | https://doi.org/10.1049/iet-epa.2015.0585 |
Public URL | https://durham-repository.worktribe.com/output/1323780 |
Accepted Journal Article
(1.9 Mb)
PDF
Copyright Statement
This paper is a postprint of a paper submitted to and accepted for publication in IET electric power applications and is subject to Institution of Engineering and Technology Copyright. The copy of record is available at IET Digital Library.
A Pragmatic Approach for Condition Monitoring of Magnetic Cores with Predominant Focus on Axial off-set Between the Fault Points
(2024)
Presentation / Conference Contribution
About Durham Research Online (DRO)
Administrator e-mail: dro.admin@durham.ac.uk
This application uses the following open-source libraries:
Apache License Version 2.0 (http://www.apache.org/licenses/)
Apache License Version 2.0 (http://www.apache.org/licenses/)
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search