The frictional behaviour of explanted PCA hip prostheses
(1998)
Journal Article
Elfick, A., Hall, R., Pinder, I., & Unsworth, A. (1998). The frictional behaviour of explanted PCA hip prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 212(H5), 395-397
Outputs (7)
Discrepancy between penetration depths derived from radiographic anddirect measurement of acetabular components (1998)
Journal Article
Hall, R., Siney, P., Craig, P., Unsworth, A., & Wroblewski, B. (1998). Discrepancy between penetration depths derived from radiographic anddirect measurement of acetabular components. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 212(H1), 57-64
The association between rates of wear in retrieved acetabularcomponents and the radius of the femoral head (1998)
Journal Article
Hall, R., Siney, P., Unsworth, A., & Wroblewski, B. (1998). The association between rates of wear in retrieved acetabularcomponents and the radius of the femoral head. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 212(H5), 321-326
Observations on the direction of wear in Charnley sockets retrieved atrevision (1998)
Journal Article
Hall, R., Siney, P., Wroblewski, B., & Unsworth, A. (1998). Observations on the direction of wear in Charnley sockets retrieved atrevision. Journal of bone and joint surgery. British volume, 80B(6), 1067-1072
Differences in the rates of penetration determined from radiographicand shadowgraphic measurements of acetabular sockets (1998)
Journal Article
Hall, R., Craig, P., Siney, P., Unsworth, A., & Wroblewski, B. (1998). Differences in the rates of penetration determined from radiographicand shadowgraphic measurements of acetabular sockets. Journal of Arthroplasty, 13(5), 570-575
Surface topography of retrieved PCA acetabular liners: proposal of anovel wear mechanism (1998)
Journal Article
Elfick, A., Hall, R., Unsworth, A., & Pinder, I. (1998). Surface topography of retrieved PCA acetabular liners: proposal of anovel wear mechanism. Journal of materials science letters (Dordrecht. Online), 17(13), 1085-1088. https://doi.org/10.1023/a%3A1006623830833
Wear in retrieved acetabular components - Effect of femoral head radiusand patient parameters (1998)
Journal Article
Elfick, A., Hall, R., Pinder, I., & Unsworth, A. (1998). Wear in retrieved acetabular components - Effect of femoral head radiusand patient parameters. Journal of Arthroplasty, 13(3), 291-295