A multi-directional wear screening device and preliminary results ofUHMWPE articulating against stainless steel
(2000)
Journal Article
Joyce, T., Monk, D., Scholes, S., & Unsworth, A. (2000). A multi-directional wear screening device and preliminary results ofUHMWPE articulating against stainless steel. Bio-Medical Materials and Engineering, 10(3-4), 241-249
All Outputs (102)
Variation in the wear rate during the life of a total hip arthroplasty- A simulator and retrieval study (2000)
Journal Article
Elfick, A., Smith, S., & Unsworth, A. (2000). Variation in the wear rate during the life of a total hip arthroplasty- A simulator and retrieval study. Journal of Arthroplasty, 15(7), 901-908
The effects of material combination and lubricant on the friction oftotal hip prostheses (2000)
Journal Article
Scholes, S., Unsworth, A., Hall, R., & Scott, R. (2000). The effects of material combination and lubricant on the friction oftotal hip prostheses. Wear, 241(2), 209-213
A novel technique for the detailed size characterization of wear debris (2000)
Journal Article
Elfick, A., Green, S., Pinder, I., & Unsworth, A. (2000). A novel technique for the detailed size characterization of wear debris. Journal of Materials Science: Materials in Medicine, 11(5), 267-271. https://doi.org/10.1023/a%3A1008992911775The accurate and detailed characterization of artificial joint wear debris is important in determining both the wear rate of prostheses and understanding the role that the debris plays in the development and progression of aseptic loosening. The nove... Read More about A novel technique for the detailed size characterization of wear debris.
Evaluation of a hip joint simulator (1999)
Journal Article
Smith, S., Burgess, I., & Unsworth, A. (1999). Evaluation of a hip joint simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 213(H6), 469-473
A comparison between gravimetric and volumetric techniques of wearmeasurement of UHMWPE acetabular cups against zirconia andcobalt-chromium-molybdenum femoral heads in a hip simulator (1999)
Journal Article
Smith, S., & Unsworth, A. (1999). A comparison between gravimetric and volumetric techniques of wearmeasurement of UHMWPE acetabular cups against zirconia andcobalt-chromium-molybdenum femoral heads in a hip simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 213(H6), 475-483
An evaluation of the tribological performance of zirconia and CoCrMo femoral heads (1999)
Journal Article
Smith, S., Elfick, A., & Unsworth, A. (1999). An evaluation of the tribological performance of zirconia and CoCrMo femoral heads. Journal of Materials Science, 34(21), 5159-5162. https://doi.org/10.1023/a%3A1004737526529Five new zirconia, five new CoCrMo and three explanted CoCrMo femoral heads were wear-tested in bovine serum for five million cycles using the Durham Hip Joint Wear Simulator. Wear was measured gravimetrically and surface topography with a 3D non-con... Read More about An evaluation of the tribological performance of zirconia and CoCrMo femoral heads.
The influence of femoral head surface roughness on the wear ofultrahigh molecular weight polyethylene sockets in cementless total hipreplacement (1999)
Journal Article
Elfick, A., Hall, R., Pinder, I., & Unsworth, A. (1999). The influence of femoral head surface roughness on the wear ofultrahigh molecular weight polyethylene sockets in cementless total hipreplacement. Journal of biomedical materials research, 48(5), 712-718
The frictional behaviour of explanted PCA hip prostheses (1998)
Journal Article
Elfick, A., Hall, R., Pinder, I., & Unsworth, A. (1998). The frictional behaviour of explanted PCA hip prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 212(H5), 395-397
Discrepancy between penetration depths derived from radiographic anddirect measurement of acetabular components (1998)
Journal Article
Hall, R., Siney, P., Craig, P., Unsworth, A., & Wroblewski, B. (1998). Discrepancy between penetration depths derived from radiographic anddirect measurement of acetabular components. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 212(H1), 57-64
The association between rates of wear in retrieved acetabularcomponents and the radius of the femoral head (1998)
Journal Article
Hall, R., Siney, P., Unsworth, A., & Wroblewski, B. (1998). The association between rates of wear in retrieved acetabularcomponents and the radius of the femoral head. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 212(H5), 321-326
Observations on the direction of wear in Charnley sockets retrieved atrevision (1998)
Journal Article
Hall, R., Siney, P., Wroblewski, B., & Unsworth, A. (1998). Observations on the direction of wear in Charnley sockets retrieved atrevision. Journal of bone and joint surgery. British volume, 80B(6), 1067-1072
Differences in the rates of penetration determined from radiographicand shadowgraphic measurements of acetabular sockets (1998)
Journal Article
Hall, R., Craig, P., Siney, P., Unsworth, A., & Wroblewski, B. (1998). Differences in the rates of penetration determined from radiographicand shadowgraphic measurements of acetabular sockets. Journal of Arthroplasty, 13(5), 570-575
Surface topography of retrieved PCA acetabular liners: proposal of anovel wear mechanism (1998)
Journal Article
Elfick, A., Hall, R., Unsworth, A., & Pinder, I. (1998). Surface topography of retrieved PCA acetabular liners: proposal of anovel wear mechanism. Journal of materials science letters (Dordrecht. Online), 17(13), 1085-1088. https://doi.org/10.1023/a%3A1006623830833
Wear in retrieved acetabular components - Effect of femoral head radiusand patient parameters (1998)
Journal Article
Elfick, A., Hall, R., Pinder, I., & Unsworth, A. (1998). Wear in retrieved acetabular components - Effect of femoral head radiusand patient parameters. Journal of Arthroplasty, 13(3), 291-295
The effect of surface topograph of retrieved femoral heads on the wearof UHMWPE sockets (1997)
Journal Article
Hall, R., Siney, P., Unsworth, A., & Wroblewski, B. (1997). The effect of surface topograph of retrieved femoral heads on the wearof UHMWPE sockets. Medical Engineering and Physics, 19(8), 711-719
Development of a six station knee wear simulator and preliminary wearresults (1997)
Journal Article
Burgess, I., Kolar, M., Cunningham, J., & Unsworth, A. (1997). Development of a six station knee wear simulator and preliminary wearresults. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 211(1), 37-47
Further studies into proximal interphalangeal joint dimensions for thedesign of a surface replacement prosthesis: medullary cavities andtransverse plane shapes (1997)
Journal Article
Ash, H., & Unsworth, A. (1997). Further studies into proximal interphalangeal joint dimensions for thedesign of a surface replacement prosthesis: medullary cavities andtransverse plane shapes. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 211(5), 377-390
Friction in hip prostheses (1997)
Journal Article
Hall, R., & Unsworth, A. (1997). Friction in hip prostheses. Biomaterials, 18(15), 1017-1026
The friction of explanted hip prostheses (1997)
Journal Article
Hall, R., Unsworth, A., Wroblewski, B., Siney, P., & Powell, N. (1997). The friction of explanted hip prostheses. British journal of rheumatology, 36(1), 20-26