Q. Wang
Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating
Wang, Q.; Wu, J.J.; Unsworth, A.; Briscoe, A.; Jarman-Smith, M.; Lowry, C.; Simpson, D.; Collins, S.
Authors
Professor Junjie Wu junjie.wu@durham.ac.uk
Professor
A. Unsworth
A. Briscoe
M. Jarman-Smith
C. Lowry
D. Simpson
S. Collins
Abstract
A novel material combination of a large diameter Biolox® Delta zirconia-toughened-alumina (ZTA) head and a pitch-based carbon fibre reinforced poly ether–ether-ketone (CFR-PEEK) MOTIS® cup has been studied. The acetabular cups were inclined at three angles and tested using Durham Hip Simulators. The different inclination angles used did not have a significant effect on the wear rates (ANOVA, p = 0.646). Averaged over all cups, the wear rates were calculated to be 0.551 ± 0.115 mm3/106 cycles and 0.493 ± 0.107 mm3/106 cycles taking into account two types of soak controls; loaded at room temperature and unloaded at 37 °C respectively. Averaged across all femoral heads, the wear rate was 0.243 ± 0.031 mm3/106 cycles. The temperature change of the lubricant caused by the frictional heat was measured in situ. Friction factors measured using the Durham Friction Simulator were lower for the worn CFR-PEEK cups compared with unworn. This correlated with the decreased surface roughness. Even though relatively high friction was observed in these hemispherical hard-on-soft bearings, the wear rate is encouragingly low.
Journal Article Type | Article |
---|---|
Acceptance Date | Mar 8, 2012 |
Online Publication Date | Mar 28, 2012 |
Publication Date | Jun 1, 2012 |
Deposit Date | May 8, 2013 |
Publicly Available Date | Mar 30, 2016 |
Journal | Journal of Materials Science: Materials in Medicine |
Print ISSN | 0957-4530 |
Electronic ISSN | 1573-4838 |
Publisher | Springer |
Peer Reviewed | Peer Reviewed |
Volume | 23 |
Issue | 6 |
Pages | 1533-1542 |
DOI | https://doi.org/10.1007/s10856-012-4617-3 |
Public URL | https://durham-repository.worktribe.com/output/1457235 |
Files
Accepted Journal Article
(1.8 Mb)
PDF
Copyright Statement
The final publication is available at Springer via http://dx.doi.org/10.1007/s10856-012-4617-3
You might also like
Biotribological and Structural Analyses of Large Diameter Ceramic on Carbon Fibre Reinforced PEEK Hip Joints with Different Inclination
(2011)
Presentation / Conference Contribution
A mathematical model of the eye lens epithelium of mammals that predicts cell density profiles in the ageing lens.
(2015)
Presentation / Conference Contribution
Prosim Simulator Wear Study of 60mm Diameter Zirconia Toughened Alumina Composite Hip Bearings: The Effect of High Cup Inclination Angle and Microseparation
(2011)
Presentation / Conference Contribution
Effect of Knee, Ankle and Hip Joint Replacements on Vitamin E Infused Highly Crosslinked UHMWPE Wear Particles Size, Shape and Morphologies Using a New Modified Base Digestion Method
(2015)
Presentation / Conference Contribution
Do structural alterations mediated by enzymatic activities influence the mechanical properties of capsular biomembranes?
(2014)
Presentation / Conference Contribution
Downloadable Citations
About Durham Research Online (DRO)
Administrator e-mail: dro.admin@durham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search