Skip to main content

Research Repository

Advanced Search

Outputs (4)

The effect of tranexamic acid on artificial joint materials : a biomechanical study (the bioTRANX study) (2014)
Journal Article
Alshryda, S., Mason, J., Sarda, P., Lou, T., Stanley, M., Wu, J., & Unsworth, A. (2015). The effect of tranexamic acid on artificial joint materials : a biomechanical study (the bioTRANX study). Journal of Orthopaedics and Traumatology, 16(1), 27-34. https://doi.org/10.1007/s10195-014-0312-0

Background Tranexamic acid (TXA) has been successfully used to reduce bleeding in joint replacement. Recently local TXA has been advocated to reduce blood loss in total knee or hip replacement; however, this raised concerns about potential adverse ef... Read More about The effect of tranexamic acid on artificial joint materials : a biomechanical study (the bioTRANX study).

Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating (2012)
Journal Article
Wang, Q., Wu, J., Unsworth, A., Briscoe, A., Jarman-Smith, M., Lowry, C., …Collins, S. (2012). Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating. Journal of Materials Science: Materials in Medicine, 23(6), 1533-1542. https://doi.org/10.1007/s10856-012-4617-3

A novel material combination of a large diameter Biolox® Delta zirconia-toughened-alumina (ZTA) head and a pitch-based carbon fibre reinforced poly ether–ether-ketone (CFR-PEEK) MOTIS® cup has been studied. The acetabular cups were inclined at three... Read More about Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating.

Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions (2011)
Journal Article
Williams, S., Wu, J., Unsworth, A., & Khan, I. (2011). Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 225(8), 783-796. https://doi.org/10.1177/0954411911404773

The purpose of this study was to compare the wear of zirconia-toughened alumina (ZTA) and alumina femoral heads tested against as-cast CoCrMo alloy acetabular cups under both standard and severe wear conditions. A new severe test, which included medi... Read More about Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions.

Tribological and surface analysis of 38mm alumina–as-cast Co–Cr–Mo total hip arthroplasties (2009)
Journal Article
Williams, S., Wu, J., Unsworth, A., & Khan, I. (2009). Tribological and surface analysis of 38mm alumina–as-cast Co–Cr–Mo total hip arthroplasties. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 223(8), 941-954. https://doi.org/10.1243/09544119jeim590

There is currently much discussion over the use of ceramic femoral components against metal acetabular cups, for use in total hip arthroplasty. The current study investigates six hot isostatically pressed alumina femoral heads of 38 mm diameter artic... Read More about Tribological and surface analysis of 38mm alumina–as-cast Co–Cr–Mo total hip arthroplasties.