Skip to main content

Research Repository

Advanced Search

All Outputs (7)

Prosim Simulator Wear Study of 60mm Diameter Zirconia Toughened Alumina Composite Hip Bearings: The Effect of High Cup Inclination Angle and Microseparation (2011)
Presentation / Conference Contribution
Giddings, D., Wu, J., Mak, S., & Khan, I. (2011). Prosim Simulator Wear Study of 60mm Diameter Zirconia Toughened Alumina Composite Hip Bearings: The Effect of High Cup Inclination Angle and Microseparation. In P. Cann, & D. Dini (Eds.), Proceedings of the International Conference on BioTribology ICoBT 2011, Imperial College London

Biotribology of 40mm Diameter MOTIS PEEK on Ceramic Hip Joints: A Detailed Simulator Study with Different Inclination Angles (2011)
Presentation / Conference Contribution
Wang, Q., Wu, J., Simpson, D., Collins, S., Briscoe, B., & Jarman-Smith, M. (2011). Biotribology of 40mm Diameter MOTIS PEEK on Ceramic Hip Joints: A Detailed Simulator Study with Different Inclination Angles. In Proceedings of the 24th Annual Congress of ISTA. concert Building, Bruges (Brugge), Belgium, europe 20-23 September, 2011

Modelling of permeability loss in membrane filtration: Re-examination of fundamental fouling equations and their link to critical flux (2011)
Journal Article
Field, R., & Wu, J. (2011). Modelling of permeability loss in membrane filtration: Re-examination of fundamental fouling equations and their link to critical flux. Desalination, 283, 68-74. https://doi.org/10.1016/j.desal.2011.04.035

A re-evaluation of the flux decline relationships in the appendix of the 1995 critical flux paper has failed to establish that one may have a critical flux in the presence of fouling that is represented by the “complete” pore blocking (n = 2) mode. I... Read More about Modelling of permeability loss in membrane filtration: Re-examination of fundamental fouling equations and their link to critical flux.

Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions (2011)
Journal Article
Williams, S., Wu, J., Unsworth, A., & Khan, I. (2011). Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 225(8), 783-796. https://doi.org/10.1177/0954411911404773

The purpose of this study was to compare the wear of zirconia-toughened alumina (ZTA) and alumina femoral heads tested against as-cast CoCrMo alloy acetabular cups under both standard and severe wear conditions. A new severe test, which included medi... Read More about Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions.

Oxidation and fusion defects synergistically accelerate polyethylene failure in knee replacement (2011)
Journal Article
Wu, J., Augustine, A., Holland, J., & Deehan, D. (2012). Oxidation and fusion defects synergistically accelerate polyethylene failure in knee replacement. The Knee, 19(2), 124-129. https://doi.org/10.1016/j.knee.2011.01.004

We have previously reported upon a cohort of patients with premature failure of such material and postulated upon the impact of abnormally high concentrations of type 2 fusion defects whereby there is a lack of particle cohesion due to incomplete dif... Read More about Oxidation and fusion defects synergistically accelerate polyethylene failure in knee replacement.