A 4D-flow cardiovascular magnetic resonance study of flow asymmetry and haemodynamic quantity correlations in the pulmonary artery
Gbinigie, Henrike; Coats, Louise; Parikh, Jehill; Hollingsworth, Kieren; Gan, Lian
Authors
Louise Coats
Jehill Parikh
Kieren Hollingsworth
Dr Lian Gan lian.gan@durham.ac.uk
Associate Professor
Abstract
Objective: In this paper we elucidate the asymmetric flow pattern and the haemodynamic quantity distributions and correlations in the pulmonary artery (PA) vasculature in healthy adults having structurally normal hearts, to provide reference on the flow characteristics in the PA and the right ventricle. Approach: Velocity data are acquired non-invasively from 18 healthy volunteers by 4D-Flow magnetic resonance imaging, resolved to 20 phases with spatial resolution 3 × 3 × 3 mm3. Interpolation is applied to improve the accuracy in quantifying haemodynamic quantities including kinetic energy, rotational energy, helicity and energy dissipation rate. These quantities are volumetrically normalised to remove size dependency, representing densities or local intensity. Main results: Flow asymmetry in the PA is quantified in terms of all the flow dynamic quantities and their correlations. The right PA has larger diameter and higher peak stroke velocity than the left PA. It also has the highest rotational energy intensity. Counter-rotating helical streams in the main PA appear to be associated with the unidirectional helical flow noticed in the left and the right PA near the peak systole. Significance: This study provides a fundamental basis of normal flow in the PA. It implies the validity to use these flow pattern-related quantitative measures to aid with the identification of abnormal PA flow non-invasively, specifically for detecting abnormalities in the pulmonary circulation and response to therapy, where haemodynamic flow is commonly characterised by increased vortical and helical formations.
Citation
Gbinigie, H., Coats, L., Parikh, J., Hollingsworth, K., & Gan, L. (2021). A 4D-flow cardiovascular magnetic resonance study of flow asymmetry and haemodynamic quantity correlations in the pulmonary artery. Physiological Measurement, 42(2), Article 025005. https://doi.org/10.1088/1361-6579/abdf3b
Journal Article Type | Article |
---|---|
Acceptance Date | Jan 22, 2021 |
Online Publication Date | Mar 5, 2021 |
Publication Date | 2021-02 |
Deposit Date | Jan 19, 2021 |
Publicly Available Date | Oct 17, 2022 |
Journal | Physiological Measurement |
Print ISSN | 0967-3334 |
Electronic ISSN | 1361-6579 |
Publisher | IOP Publishing |
Peer Reviewed | Peer Reviewed |
Volume | 42 |
Issue | 2 |
Article Number | 025005 |
DOI | https://doi.org/10.1088/1361-6579/abdf3b |
Files
Published Journal Article
(1.8 Mb)
PDF
Publisher Licence URL
http://creativecommons.org/licenses/by/4.0/
Copyright Statement
Original content from this<br />
work may be used under<br />
the terms of the Creative<br />
Commons Attribution 4.0<br />
licence.<br />
Any further distribution of<br />
this work must maintain<br />
attribution to the<br />
author(s) and the title of<br />
the work, journal citation<br />
and DOI.
You might also like
Formation and evolution of vortex rings with weak to moderate swirl
(2023)
Journal Article
Flow separation from polygonal cylinders in an incident flow
(2023)
Journal Article
A review of experiments on stationary bluff-body wakes
(2022)
Journal Article
Large Eddy Simulation of incident flows around polygonal cylinders
(2021)
Journal Article